Partial discharge test procedure

The most recognized standard that we are aware of was developed by vde in germany and applies to testing of optocouplers. Offline measurements occur where the machine is disconnected and. The detection and measurement by the wideband apparent charge method of partial discharges occurring in liquidfilled power transformers and shunt reactors during dielectric tests are covered. It is the only online electrical test that correctly identifies and warns of pending stator winding failure mechanisms such as loose windings, contamination. Seba kmt oscillating wave test system owts is used to identify, evaluate and locate partial discharge pd faults in hv high voltage cable insulation, cable joints and cable terminations. Characteristics of partial discharge depend on the type, size and location of the defects, insulation type, voltage, and cable temperature. We have adopted the method described in vde 0884 to test for partial.

For example to simulate the corona in air, the electrode needle plate can be used. These diagnostic tests are usually carried out at a frequency of 0. Partial discharge pd is a localized electrical discharge that only partially bridges the insulation between conductors and which may or may not occur adjacent to a conductor. Depending on the test period, partial discharge level stays approximately stable. Partial discharge is a cry for help from the insulation of high voltage equipment. Gts uses a full range of the latest online and offline test equipment to diagnose the condition of all your installations. Data collected during the procedure is compared to measurement values of the same cable gathered during the acceptancetest. What is partial discharge in high voltage cables, switchgear. When speaking of partial discharge, the most important standard that every expert will refer to is iec 60270. Offline measurements occur where the machine is disconnected and the testing occurs from an external source. Ieee guide for the measurement of partial discharges in ac. Guide for field pd tests for liquidfilled power transformers. Apply vlf in order to detect and measure partial discharge.

Sedding, qualitrol iris power 1 abstract it has long been known that comparing the partial discharge results obtained from a single machine is a valuable. It also provides asset managers with the critical information to target maintenance resources to the areas that require the most attention. This standard covers the measuring instrument, calibrator characteristics, test circuits, calibration procedure, and partial discharge measurement during inducedvoltage tests. We use two technologies for detecting partial discharge, namely. Tan delta versus partial discharge testing on cables.

First, we will present a few technical concepts relating to partial discharges. Routine tests and type tests of transformers electrical4u. This paper presents several case studies of the use of these new partial discharge test technologies on generators. Offline partial discharge testing offline partial discharge testing uses a similar. Netaworld online versus offline partial discharge testing for cable assessment 65 figure 1. Partial discharge testing is a very useful way of assessing battery condition, but it is not ideal in every application. Partial discharge test partial discharge pd is a phenomenon that has been around for decades and probably was observed in rotating equipment as higher voltages came into use. The partial discharge detector provides display of pd pulses on.

Thus pd can be detected in a very wide range of frequencies, and this will impact what is actually measured. Our pd testing service does not require shutdown and is. As a result, its measurement is standard procedure in the factory testing of many types of high voltage equipment. The magnitude of pd is measured in pico coulombs pc. Highvoltage test techniques partial discharge measurements iec 60270.

Online partial discharge testing is a great tool for the testing of cable systems and electrical equipment without having to take the equipment out of service, as the measurement does not require galvanic coupling to the high voltage conductors. Over 85% of disruptive failures in hv and mv equipment are partial discharge related. Perhaps the most significant factory test made on the insulation of full reels of extruded cable is the partial discharge test. Partial discharge measurement is a critical criterion for inspecting the quality of power cables and cable accessories during onsite cable commissioning. First, a onesecond test at rated voltage checks for leakage current. Increasing the test voltage causes almost no partial discharge level. Partial discharge pd is a phenomenon that has been around for decades and probably was observed in rotating equipment as higher voltages came into use. The partial discharge measurement is a suitable method to detect and localize imperfections in the high voltage insulation system and provides a procedure for.

Standard test method for detection and measurement of partial. Data obtained through partial discharge testing and monitoring. Transformer routine test partial discharge measurement. We regularly share our findings, publish technical papers, and speak at events, sharing our knowledge and learnings across the globe. In an effort to promote a better understanding of partial discharge pd, this paper attempts to provide simplified models and relate the characteristics of these models to the interpretation of pd test results. Partial discharge test and monitoring systems can be supplied in the form of handheld tools, as well as bigger, transportable diagnostic products. Partial discharge testing and acceptance testing services. This test is especially important for medium voltage multilayer laminated busbars, inverters, and any critiical power conductor applications where electrical insulation is of. Partial discharge pd occurs in the stator insulation system of rotating machines, where local electric field stress exceeds the local electrical strength. This standard applies to the measurement of pd in electrical apparatus or systems when testing with ac voltage up to 400 hz or with dc voltage. In general for a site that has infrequent shutdowns partial discharge would be the way to go and it can provide information on problem cables that you can then check with tan delta during a shutdown.

This test method is also useful in determining quantities such as apparent charge and. Ultrasound for surface discharge ultrasound detection of surface discharge is a wellestablished worldwide methodology. Highvoltage test techniques partial discharge measurements. Why partial discharge testing makes good sense omicron.

European standard en 60270 norme europeenne europaische norm march 2001 ics 17. Partial discharge is a localized electrical discharge that can occur at voids, gaps and similar defects in medium and high voltage cable systems. Jul 07, 2016 online partial discharge testing is a powerful tool you can use to assess machines while in operation to prevent high costs associated with equipment failure. A rising trend as test voltage rises indicates damage or aging.

Partial discharge testing and acceptance testing services global. Ieee guide for the measurement of partial discharges in ac electric machinery 1. This unique online method can directly assess the solid insulation of power transformers and detect the deterioration of interturn insulation, disks insulation, hv to lv insulation, tap changer, and. Online partial discharge testing equipment hv technologies. The interpretation of results is aided by the use of ea technologys partial discharge measurements database that contains over 20,000 records of surveys of switchgear using partial discharge detection equipment. Accurate, reliable and reproducible pd measurements based on iec 60270, iec 60840 and iec 62067 standards, can be generated by a guided workflow for routine tests and type tests. Online testing occurs when the rotating machine is kept running or energized. Partial discharge theory and applications to electrical. A partial discharge measurement system basically consists of. Iec 60270 2000 highvoltage test techniques partial discharge measurements iec 600763 20 power transformerspart 3. Partial discharge is caused by discontinuities and flaws in high voltage electrical insulation and, if left undetected, can eventually lead to the full breakdown of the insulation system. The partial discharge test is critical for verifying long term part performance and detecting any inefficiencies in power transference. What is partial discharge pd and what are the different.

Typical offline pd test connections influence of voltage on tan delta amplitude. Partial discharge is a breakdown of a small area of insulation, which is subject to a high voltage. The test is typically performed over a range of test voltages to identify the different defects and their inception and. Similar to offline partial discharge testing, the challenge of this test is that the equipment must be taken out of service. A partial discharge, or pd, is a localized dielectric breakdown of a small portion of the electrical insulation.

May 02, 2018 testing involves applying a voltage conducive to partial discharge and then directly or indirectly measuring the discharge current pulses using calibrated pd sensors. Astm d1868 20 standard test method for detection and. If not properly addressed, partial discharge will erode the cable insulation, usually forming a treeshaped pattern of deterioration electrical tree and eventually result in complete breakdown and. Ac dielectric test systempower frequency voltage withstand test iron loss tester. It may disconnect the coupling capacitor ck and the test specimen ct from the voltage source during the short duration pd phenomena and ck is a storage capacitor or quite a stable voltage source during the short period of the partial discharge. Test procedures and general evaluation guidelines are given in the relevant ieee 400 series standards. Partial discharges pd are evidence of a degrading insulation system. Single conductor shielded cables and assemblies thereof. Kinectrics offers a variety of offline and online nondestructive testing techniques for power transformers, including online partial discharge, dga, moisture test, frequency response analysis, and bushing testing for small and large generation, and transmission class power transformers. A partial discharge pd is an electrical breakage phenomenon that is located in an insulating medium between two conductors that are at different potential. Partialdischarges are electrical arks which form the surges between electrodes of any area of the insulating media of a transformer between the conductors. Chapter 8 partial discharge pd hv and ehv power cable systems.

Partial discharge pd measurement instruments for high voltage cables. Partial discharge analysis on rotating machines omicron. Calibrators are usually disconnected during the discharge testing. The partial discharge measuring device includes a circuit with the following components. Online partial discharge testing on rotating machines.

Partial discharge severity tables and pd database for motors. Pd occurs whenever there is a stressed region due to some impuritycavity inside the insulation or when there is a protrusion outside it. Partial discharge test of transformer top electrical engineers. There are two different methods for partial discharge testing. Recommended commissioning test procedures and success criteria for vlf test. These methods pertain to pd testing while offline, which means the. Partial discharge testing plays a critical role in determining the health of your electrical assets and ensuring maximum uptime. Compared with other dielectric tests, the differentiating character of partial discharge measurements allows localized weak points of the insulation to be identified. About partial discharge pd what is partial discharge. The partial discharge measurement is a suitable method to detect and localize imperfections in the high voltage insulation system and provides a procedure for quality assurance of electrical equipment. Partial discharge theory and applications to electrical systems.

Partial discharge test of transformer is very important test that helps us to detect any defect in transformer insulation that helps us to detect any defect in transformer insulation partial discharge occurs as a result of the presence of moisture in liquid insulators or the presence of cavity in insulation due to defects in the manufacture of solid insulators. The partial discharge testing if they have the hardware installed can be done live. With many possible applications for pd testing, accessories can help maximize the benefit of your pd test instruments. Nov 30, 2016 a vlf hipot test is a gonogo test and is not a diagnostic test, but is one of the best ways to check the ac integrity of an electrical asset to determine a pass or fail result. Whether you need a sensor, measuring impedance, coupling capacitor or calibrator, we offer a complete line of doble partial discharge testing accessories to help refine your pd testing capabilities. Test results show that machines with deteriorated windings have a partial discharge activity at least 30 times higher than good windings. Apr 23, 2010 partial discharge is caused by discontinuities and flaws in high voltage electrical insulation and, if left undetected, can eventually lead to the full breakdown of the insulation system. Partial discharge measurement techniques electrom instruments. Partial discharge test conditions test 1 test 2 test 3. Very low frequency vlf withstand testing the basics. Online partial discharge testing is a method of inspecting the insulation of electric power systems while equipment remains energized and in service.

But, with the introduction of inverter drives used to power electric motors. Jun 04, 2019 one of the benefits of using our partial discharge testing service is our ability and experience at interpreting the results. The test procedure is conducted with a coupling capacitor of pf, measuring capacitor of 100pf, high voltage pd free transformer, and discharge detector in wide band mode. This test is especially important for medium voltage multilayer laminated busbars, inverters, and any critiical power conductor applications where electrical insulation is of paramount importance. Iec 6003427 24 covering offline test methods and iec 60034272 25 regarding online pd testing. The pd reader uses easytounderstand knowledgebased methods to. Dc test sets cannot be used as a voltage source for tan delta or partial discharge testing. High voltage partial discharge hvpd are at the forefront of partial discharge testing and monitoring, and as such, have established themselves as thought leaders in the field. In addition to the measured partial discharge level, the below conditions should also be considered in transformers.

Value of partial discharge testing for power transformers pd measurement is a fundamental tool used to assess the condition of oilfilled or cast resin power transformers. Offline measurements occur where the machine is disconnected and the testing occurs from an. Multiple conductor cables with individually shielded conductors within an outer covering. What is partial discharge pd and under what conditions does it occur examples of pd in power cables, transformers, switchgear and stator windings pd measurement as a factory acceptance test of equipment offline pd testing at site online condition monitoring of power cables, transformers, switchgear and machines. Insulation levels, dielectric tests and external clearances in air ieee c57. Partial discharge test of transformer is very important test that helps us to detect any defect in transformer insulation partial discharge occurs as a result of the presence of moisture in liquid insulators or the presence of cavity in insulation due to defects in the manufacture of solid insulators.

Relationship between capacitive and resistive currents the ratio of the two currents i r i c is the tangent of the angle. Pdetector incorporates all 5 types of online pd sensor technology. This routine test aims to measure the partial discharges which may occur in the transformer insulation structure during test. An oscilloscope coupled with indicating equipment, a voltmeter connected to the high voltage supply, and an amplifier coupled to the oscilloscope to detect existence of partial discharge and individual discharge pulses. Ultrasound detection of discharge relies on detecting the sound emissions given off by the discharge. Partial discharge testing pd the partial discharge test is critical for verifying long term part performance and detecting any inefficiencies in power transference. Jul 03, 2017 why partial discharge testing makes good sense july 3, 2017 partial discharge pd phenomena are in many cases the preliminary stage of a complete breakdown of the electrical insulation in highvoltage assets, which can lead to unplanned outages, high repair or replacement costs and lost production. Partial discharge test pd tester electrom instruments. Partial discharge start and cease voltages are above the operating voltage. Partial discharge academy listen to the difference between background noise and partial discharge. Icea t24380 partial discharge test procedure engineering360. In the late 1980s, manufacturers have produced equipment which can reliably test for very low values of partial discharge. In electrical engineering, partial discharge pd is a localized dielectric breakdown db which does not completely bridge the space between the two conductors of a small portion of a solid or fluid electrical insulation ei system under high voltage hv stress.

The basics of partial discharge testing hv technologies, inc. Partial discharge analysis on power cables omicron. When partial discharge occurs in a gas, it is usually known as corona. Partial discharges occur due to the existence of a nonuniform high electric field and have the effect of deterioration over time of the insulation system, that is to say reducing its. Why partial discharge testing makes good sense july 3, 2017 partial discharge pd phenomena are in many cases the preliminary stage of a complete breakdown of the electrical insulation in highvoltage assets, which can lead to unplanned outages, high repair or replacement costs and lost production. This factory test procedure applies to the detection and measurement of partial discharges occurring in the following types of solid dielectric cables. Using online monitoring to identify partial discharge can help avoid service failures, extend the time between rewinds and outages and plan maintenance based on machine condition. Chapter 8 partial discharge pd hv and ehv power cable. This is usually done at power frequency, but can also be carried out at very low frequency and at some voltage significantly higher than normal working voltage to ground. Although the batteries remain in service should they be called upon to supply power at the point of deepest discharge during the test they will only have 20% of their. Partial discharge is generally accepted as the predominant cause of long term degradation and eventual failure of electrical insulation. Another onesecond test checks for partial discharge pd at 1.

Pdstar is the ideal tool for conditionbased maintenance programs. Test procedures for extended timetesting of wire and cable insulations for service in wet locations ansiicea t24380 partial discharge test procedure ansiicea p32382 shortcircuit characteristics of insulated cable icea t25425 guide for establishing stability of volume resistivity for conducting polymeric compounds of power cables ansi. The general procedure for partial discharge testing is to raise the voltage to 1. Noise reduction methods necessary for field tests of partial discharge usually include the use of an independent test voltage source such as a motorgenerator, power line and high voltage filters, shielding and sometimes the use of bridge detection circuits. One of the major factors contributing to shortened lifetimes of high voltage generators and motors is deterioration of stator winding insulation. These partial discharge testers can take the role of quality assurance for product manufacturing or offsite plant analysis and mapping at almost any voltage the customer requires. By applying the voltage to the electrodes, the corona will be occurred in needle electrode. Recommended maintenance test procedures and success criteria for offline pd measurements at overvoltage 59 table 17.

988 617 1343 947 1350 1183 422 535 543 1041 1018 1051 76 1293 742 1615 651 1462 905 636 658 1082 1362 656 1425 376 908 575 207 147 1287 559 573 294 84 1471 1089 845